Overview
NLI-RT12, fuel cell type sensor, detects gas concentration by measuring current based on the electrochemical principle, which utilizes the electrochemical oxidation process of target gas on the working electrode inside the electrolytic cell, the current produced in electrochemical reaction of the target gas are in direct proportion with its concentration while following Faraday law, then concentration of the gas could be detected by measuring value of current.
Key Features
Low consumption, high precision, high sensitivity, wide linear range, good anti-interference ability, excellent repeatability and stability.
Applications
It is widely used in H2 concentration detection in commercial, vehicle, small generator field and other fields.
Technical Specifications
| Item | Parameter |
| Detection gas | H2 |
| Measurement range | 0~2000ppm |
| Max detecting concentration | 5000ppm |
| Sensitivity | (0.5~1.5)nA/ppm |
| Resolution | 1ppm |
| Response time(T90) | <30S |
| Load resistance(recommended) | (500/1K/2K)Ω |
| Repeatability | <5%output value |
| Output linearity | linear |
| Temperature range | -10°C~50°C(common) -40°C~70°C(occasionally) |
| Humidity range | 15%~90%RH |
| Pressure range | Normal atmosphere ±10% |
| Anticipated using life | 10 years |