DC Power Supply DIN Rail 12V/24V/36V/48V 25W/35W/50W/100W/150W/200W/350W Switching Power Supply

SKU: BX-PWR-73786 Category:

Product Details & Specifications

Product Description

Specification
DR-60 60W Din Rail Power Supply
Project Technical index
Output DC voltage 12V 24V
Rated current 4.5A 2.5A
Rated power 54W 60W
Ripple and noise  <120mV <150mV
Voltage accuracy ±1%
Ripple and noise ±10%
Load adjustment rate ±1%
Linear adjustment rate ±1%
Input Voltage range / frequency 85-264VAC 47Hz~63Hz (120VDC~370VDC)
Efficiency (typical)  >82% >84%
Working current <1.2A 110VAC <0.8A 220VAC
Shock Current 110VAC 15A, 220VAC 30A
Start,Rise,Hold time 100ms,30ms,21ms :110VAC/100ms,30ms,100ms :220VAC
Protect overload protection 105%-150% Type:production mode:burp modde automatic recovery after the abnormal condition is lifted
Short circuit protection VO The output abnormal condition will be restored automatically after it is removed after the power is restarted
Environmental Science Working temperature and humidity -10ºC~+50ºC;20%~90RH
Working temp.and humidity -20ºC~+85ºC;10%~95RH
Safety regulations Pressure Resistance O/P-I/P,I/P-O/P:3KVAC
Isolation Resistance I/P-O/P, O/P-Shell,O/P-Shell :500VDC/100MΩ
Other size 78*93*56mm
Net weight / gross weight 270/290g
60W Ultra Slim Step Shape DlN Rail
HDR-60 series
SPEClFlCATlON
MODEL HDR-60-5 HDR-60-12 HDR-60-15 HDR-60-24 HDR-60-48
OUTPUT DC VOLTAGE 5V 12V 15V 24V 48V
RATED CURRENT 6.5A 4.5A 4A 2.5A 1.25A
CURRENT RANGE 0 ~ 6.5A 0 ~ 4.5A 0 ~ 4A 0 ~ 2.5A 0 ~ 1.25A
RATED POWER 32.5W 54W 60W 60W 60W
RlPPLE & NOlSE(max.) Note.2 80mVp-p 120mVp-p 120mVp-p 150mVp-p 240mVp-p
VOLTAGE ADJ. RANGE 5.0 ~ 5.5V 10.8 ~ 13.8V 13.5 ~ 18V 21.6 ~ 29V 43.2 ~ 55.2V
VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
LlNE REGULATlON ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LOAD REGULATlON ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
SETUP, RlSETlME 500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load
HOLD UP TlME(TYP.) 30ms/230VAC 12ms/115VAC at full load
lNPUT VOLTAGE RANGE 85 ~ 264VAC(277VAC operational ) 120 ~ 370VDC(390VDC operational )
FREQUENCY RANGE 47 ~ 63Hz
EFFlClENCY(TYP.) 85% 88% 89% 90% 91%
AC CURRENT(TYP.) 1.2A/115VAC 0.8A/230VAC
lNRUSH CURRENT(TYP.) COLD START 30A/115VAC 60A/230VAC
PROTECTlON OVERLOAD 105 ~ 160% rated output power
Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed
Constant current limiting 
within 50% ~100% rated output voltage, recovers automatically after fault condition is removed
OVER VOLTAGE 5.75 ~ 6.75V 14.2 ~ 16.2V 18.8 ~ 22.5V 30 ~ 36V 56.5 ~ 64.8V
Protection type : Shutdown o/p voltage, re-power on to recover
ENVlRONMENT WORklNG TEMP. -30 ~ +70ºC (Refer to ‘Derating Curve’)
WORklNG HUMlDlTY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMlDlTY -40 ~ +85ºC , 10 ~ 95% RH non-condensing
TEMP. COEFFlClENT ±0.03%/ºC (0 ~ 50ºC )RH non-condensing
VlBRATlON 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along x,Y, Z axes; Mounting: Compliance to lEC60068-2-6
OPERATlNG ALTlTUDE 2000 meters
OVER VOLTAGE CATEGORY According to EN61558, EN50178,EN60664-1, EN62477-1altitude up to 2000 meters
SAFETY  WlTHSTAND VOLTAGE l/P-O/P:4kVAC
lSOLATlON RESlSTANCE l/P-O/P:100M Ohms / 500VDC / 25ºC  / 70% RH
OTHERS MTBF 3524.8k hrs min. Telcordia SR-332(Bellcore); 927.6k hrs min. MlL-HDBk-217F(25ºC  )
DlMENSlON 52.5*90*54.5mm(W*H*D)
PACklNG 190g;60pcs/13kg/0.91CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12′ twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altitude higher than 2000m(6500ft).
NDR-120 120W Rail Type Switching Power Supply
Project Technical index
Output DC voltage 12V 24V 48V
Rated current 10A 5A 2.5A
Rated power 120W 120W 120W
Ripple and noise  <120mV <120mV <150mV
Voltage accuracy ±2% ±1%
Output voltage regulation range ±10%
Load adjustment rate ±1%
Linear adjustment rate ±0.5%
Input Voltage range 85-264VAC 47hz-63hz (120vdc-370vdc: DC input can be realized by connecting AC / L +, AC / N (-))
Efficiency (typical)  >86% >88% >89%
Working current <2.25A 110VAC <1.3A 220VAC
Impulse current 110VAC 20A, 220VAC 35A
Start, rise, hold time 500ms,70ms,32ms :110VAC/500ms,70ms,36ms :220VAC
Protect overload protection 105% – 150% type: protection mode: automatic recovery after removing the abnormal condition of constant current mode
Overvoltage protection When the output voltage is more than 135%, the output will be turned off. It will recover automatically after the abnormal conditions are removed
Short circuit protection +VOWhen the abnormal condition of output is released, it will recover automatically
Environmental Working temperature and humidity -10ºC~+60ºC;20%~90RH
Storage temperature and humidity -20ºC~+85ºC;10%~95RH
Safety/EMC Withstand voltage Input output: 3kVac input ground: 1.5kVac output ground: 0.5kvac for 1 minute
Leakage current <1mA/240VAC
Isolation resistance Input output, input shell, output shell: 500VDC / 100M Ω
Other size 40*125*113mm
Net weight / gross weight 707/750g

Company Profile

Our Team

Shipping&Delivery

FAQ
Q1:How many Voltage you can supply? A: 12v,24v,48v,50,60,110v(Depend on items).

Q2Can I have a sample order? A: Yes, we welcome sample order to test and check quality.Mixed samples are acceptable.

Q3Do you have any MOQ limited for the order? A: Low MOQ, 1pc for sample checking is available. At the same time, we have overseas warehouses so that you can get the products faster.

Q4How do you ship the goods and how long does it take to arrive? A: We usually ship by DHL, UPS, FedEx or EMS. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.

Q5Do you offer guarantee for the products? A: Yes, we offer warranty to our products.

Q6: How to deal with the faulty? A: Firstly, our products are produced in strict quality control system and the defective rate will be less. Secondly, during the guarantee period,we will send new product with new order for small quantity. For defective batch products, we will repair them and resend them to you or we can discuss the solution including re-call according to real situation.