H101-CO2-Z8S-U-40kP Photoacoustic PAS Carbon Dioxide CO2 Sensor

SKU: VCF-KG3 Category:

Overview

The H101-CO2-Z8S-U-40kP CO2 gas sensor, hereinafter referred to as the PAS sensor, is a compact sensor with a wide measurement range. Employing the photoacoustic principle, it effectively detects CO2 in the air. The sensor features excellent selectivity, operates independently of oxygen, and has an extended lifespan. With built-in temperature and humidity compensation, it offers enhanced usability. The PAS sensor represents a high-performance design, integrating photoacoustic spectroscopy detection technology with sophisticated circuit design and advanced algorithms. Its dimensions measure 20x15x7.8mm, making it suitable for space – constrained applications.

Key Features

  • Wide Range: Offers a measurement range of 400 – 5000 ppm, extendable up to 40000 ppm.​
  • High Sensitivity: Capable of detecting even minute changes in CO2 concentrations.​
  • Stability: Demonstrates excellent long – term stability.​
  • Compensation and Output: Features temperature and humidity compensation, ensuring a linear output.​
  • Output Interface: Provides a UART (TTL 3.3V) output interface for easy integration.​
  • Long Lifespan: Has a lifespan of over 10 years.​
  • Resistance: Resistant to water vapor interference and immune to poisoning.

Applications

  • Automotive Air Conditioning Systems: Enables precise control of cabin air quality by monitoring CO2 levels.​
  • Air Purification Devices: Facilitates efficient purification by detecting CO2 concentrations and triggering purification mechanisms.​
  • Air Quality Monitoring Equipment: Plays a crucial role in providing accurate CO2 data for comprehensive air quality assessment.​
  • Smart Homes: Allows for intelligent control of home environments based on CO2 levels, enhancing comfort.​
  • Fresh Air Systems: Helps regulate the intake of fresh air by sensing indoor CO2 levels.

Technical Specifications

Parameter Details
Model H101-CO2-Z8S-U-40kP
Detection Gas CO2
Supply Voltage Light source: (5.0±0.05) V; System: (3.3±0.3) V
Average Current <15 mA (@5 V); <2 mA (@3.3 V)
Peak Current 300 mA (@5 V)
Interface Level 3.3 V
Measurement Range 400 – 5000 ppm (expandable to 40000 ppm)
Output Signal UART (TTL 3.3 V)
Warm-up Time 60 s
Response Time T63% < 60 s
Operating Temperature -10~60 °C
Pressure Range 750~1150 hPa
Operating Humidity 0~95%RH (non – condensing)
Storage Temperature 5~40 °C
Lifespan >10 years
Accuracy (400 – 2000 ppm) Resolution: 10 ppm; Accuracy: ±(50 ppm + 3% reading)
Accuracy (2001 – 5000 ppm) Accuracy: ±(40 ppm + 3% reading)